Voltage Probe Manual and Data

North Star Research Corporation

 

Standard Voltage Probe Data

High Voltage Probes Up to 400 kV

 

High Voltage Probes

High voltage measurements have a variety of different requirements, and our PVM series and VD series probes are designed for most of these requirements. The PVM probes are designed for wide bandwidth and ease of portability where a variety of measurements must be made. The VD series probes are designed for use at higher voltage ranges, and where physical stability is required.

Specialty Probes PVM series probes with PVM-5 on top and PVM-10 on the bottom

The design of the probes is unique. The probe comes fully adjusted without any requirement to further adjust the probe in the field. Stray capacitances internal to the probe are factory calibrated. Stray capacitances due to proximity effects are minimied by the unique conductor placement.

Low temperature and voltage coefficient resistors and capacitors are used throughout the probe to provide maximum measurement accuracy. The probe has a rugged nylon housing, and it is filled with dielectric oil for maximum high voltage stability.

Our PVM Series probes our available with either 1000:1 or 2000:1 calibration factors at the time of order.

Voltage Probe Specifications

PVM Series Portable High Voltage Probes to 60 kV DC

PVM series high voltage probes are designed for general use, and for exceptional high frequency response. The probes have applications ranging from automotive ignition to excimer laser system measurement to EMI measurement. They are factory calibrated, and they do not require adjustment. In general the probes are for use with 1 Megohm oscilloscopes, but we also offer an optional switch which can compensate for various measurement instruments such as 10 Megohm meters as well. These units are intended for a wide range of applications where portability and ease of use are essential.

 

Model Number

PVM-1

PVM-2

PVM-3

PVM-4

PVM-5

PVM-6

PVM-11 (PVM-10)

PVM-12

Max DC/Pulsed V (kV)

40/60

40/60

40/60

40/60

60/100

60/100

10/12

25/30

Max Frequency (Mh.)

80

80

40

110

80

80

50

80

Cable Impedance (ohms)

50

50

50

93

50

50

50

50

DC - 2 H.accuracy

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

2 H. - 200 H. accuracy

<1 %

<1. %

<2. %

<1. %

<1 %

<1 %

<1.5 %

<1.5 %

200 H. - 5 Mh. accuracy

<1.5%

<1.5%

<3%

<1.5%

<1.5%

<1.5%

<2.%

<2.%

> 5 Mh. Accuracy

<3%

<3%

<4%

<5%

<3%

<4%

<4%

<4%

Input R/C (Megohm/pf)

400/13

400/13

400/10

400/10

400/12

400/12

100(50)/15

300/7

Cable Length (ft./m)

15/4.5

30/9

100/30

15/4.5

15/4.5

30/9

15/4.5

15/4.5

Standard Divider Ratio

1000:1

1000:1

10,000:1

1000:1

1000:1

1000:1

1000:1 (100:1)

1000:1

Length (inches/cm.)

19/47

19/47

19/47

19/47

19/47

19/47

7/18

9/23

*美NORTH STAR 高壓探頭

Add -2 to any PVM-1 - PVM-6 or PVM-12 part number for 2000:1 ratio

VD Series High Voltage Probes 60 to 300 kV DC

Specialty Probes

VD series high voltage probes are floor standing high voltage probes which are designed for rugged day in - day out use. They are used in a wide range of applications ranging from evision tube manufacturing to radar to advanced particle accelerator applications. Resistors with an extremely low voltage coefficient of resistance are used, and all capacitors are temperature, frequency, and voltage stabilied for the best possible performance. The probes all have field defining toroids as a standard item in order to minimie the proximity effect (stray *美NORTH STAR 高壓探頭capacitance) and maximie the reproducibility of the measurement. The high and low frequency calibrations are carefully matched before shipment. Very high frequency cable effects are also carefully compensated so accurate measurements can be made even when the cable length exceeds the pulse duration. No adjustments are necessary once the probes have been factory calibrated.

Model Number

VD-60

VD-100

VD-150

VD-200

VD-300

VD-400

Max DC/Pulsed V (kV)

60/120

100/180

150/240

200/300

300/420

400/550

Max Frequency (Mh.)

20

20

20

16

12

8

Cable Length (ft.)

30

30

30

30

30

30

DC accuracy

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

10 H. - 1 Mh. Accuracy

1 %

1 %

1 %

2 %

2.5 %

3 %

>1 Mh Accuracy

3 %

3 %

3 %

3 %

4 %

4 %

Resistance (Megohms)

800

1600

2000

2800

4500

7000

Height (inches/cm.)

20/50

24/60

30/75

40/99

54/135

72/180

Diameter (in/cm.)

11/28

11/28

12/29

16/40

24/61

24/61

Capacitance (approx. pf)

27

25

27

24

20

16

Base Diameter(in/cm.)

10/25

10/25

12/30

20/50

30/76*

30/76

Standard Divider Ratio

10,000:1

10,000:1

10,000:1

10,000:1

10,000:1

10,000:1

 

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯數(shù)字),如:三加四=7
北京志鴻恒拓科技有限公司

北京志鴻恒拓科技有限公司

地址:北京市朝陽區(qū)建國路88號soho現(xiàn)代城

© 2025 版權(quán)所有:北京志鴻恒拓科技有限公司  備案號:京ICP備16029562號-5  總訪問量:735560  sitemap.xml  技術(shù)支持:化工儀器網(wǎng)  管理登陸

国产后入清纯学生妹| 在线天堂中文最新版网| 亚洲精品无码久久久久y| 欧美黑人添添高潮a片www| 老师久久精品人人爽人人爽澡| 最近韩国日本免费高清观看直播| 国产精品 高清 尿 小便 嘘嘘| 中文人妻熟妇乱又伦精品| 强奷漂亮少妇高潮A片| 人妻体验按摩调情BD| 非缘勿扰电视剧全集36免费观看| 一夜新娘第一季全集免费观看| 久久久不卡国产精品一区二区| 快穿名器高h喷水荡肉爽文| 韩国三级丰满少妇高潮| 校花夹震蛋上课自慰爽死| 中国老妇XXXX性开放| 一区二区三区无码被窝影院| 精品成在人线av无码免费看| 人人澡人人妻人人爽人人蜜桃| 午夜三级| 国产精品无码翘臀在线观看| 51午夜精品免费视频| 东北体育生巨大粗爽gay| 亚洲乱妇亚洲乱妇xinglu| 小浪货腿张开水好多啊学生视频| 上边一面亲下边一面膜的程序| 亚洲精品日韩一区二区电影| 用舌头去添女人下面是不是真爱| 日本亚洲精品无码区国产电影| 国内精品久久久久影院欧美| 麻豆国产尤物av尤物在线观看| 国产精品成人第一区二区三区| 肥大BBWBBW高潮喷水| 少爷屁股卡在墙上被侍卫调教| 真人作爱90分钟免费看视频| 亚洲欧美日韩一区二区| 国产人妻久久精品二区三区特黄| 欧洲黑大粗无码免费| 免费无码a片一区二区三区| 社保15年后每月拿多少|